62,000 watt Coco grow.

avant gardener

Member
Veteran
that's quite a stretch.
i don't envy you having to tie all that stuff back either.
on payday i might though.

whatever else, do please wear some eye protection around all those vert bulbs.
 

ThePizzaMan

Active member
Veteran
I just came in my pants. One of the nicest threads I have ever seen...elite shit. If you and JackMayOff touched dick tips...the world would implode!

Much Respect!


TpM
 

Tactician

Member
Nice setup VP. I have a couple questions on the electrical. Did the inspector allow stranded 14awg to be wirenutted to solid copper 14awg. It is permitted, but is frowned upon by the 3 electrical inspectors I've worked with. They prefer to see hardwired 14awg soow from the flip relay screw terminals to the mogul/junction box. Some of these IEs can be picky, but they see it as business that is income based, not a home theatre system being install, but a profit making venture, so why not be like Mike Holmes....lol

It looks like you're using 1 flip relay for 2 ballasts and 4 lights, not sure, but that's how it looks. Did your inspector permit that or overlook. The electrical inspectors I've worked with don't permit that, especially with flip relays.

Are there smoke, fire, and heat sensors wired in to provide emergency power off. It isn't mandatory, but a welcome feature for IE. I have a couple pics of some work I've done, do you mind if I post here VP.
 

VagPuncher

Balls Deep!!
ICMag Donor
Veteran
I have a couple questions on the electrical. Did the inspector allow stranded 14awg to be wirenutted to solid copper 14awg. It is permitted, but is frowned upon by the 3 electrical inspectors I've worked with. It looks like you're using 1 flip relay for 2 ballasts and 4 lights, not sure, but that's how it looks. Did your inspector permit that or overlook. The electrical inspectors I've worked with don't permit that, especially with flip relays.

Are there smoke, fire, and heat sensors wired in to provide emergency power off. It isn't mandatory, but a welcome feature for I E.

I have to be honest, I have no idea what the inspector looked at or did, but he did come and it did pass. He was there for about 8 min.

;)
 

FunkBomb

Power Armor rules
Veteran
Your setups are badass.

I see you have some rooms with horizontal reflectors, some with bare bulbs, and others with vertical reflectors. Which setup do you find gives you the best yield in the end? Also, what do you see as the advantages and disadvantages to each in such large operations?

-Funk
 

VagPuncher

Balls Deep!!
ICMag Donor
Veteran
Nice setup VP. I have a couple questions on the electrical. Did the inspector allow stranded 14awg to be wirenutted to solid copper 14awg. It is permitted, but is frowned upon by the 3 electrical inspectors I've worked with. They prefer to see hardwired 14awg soow from the flip relay screw terminals to the mogul/junction box. Some of these IEs can be picky, but they see it as business that is income based, not a home theatre system being install, but a profit making venture, so why not be like Mike Holmes....lol

It looks like you're using 1 flip relay for 2 ballasts and 4 lights, not sure, but that's how it looks. Did your inspector permit that or overlook. The electrical inspectors I've worked with don't permit that, especially with flip relays.

Are there smoke, fire, and heat sensors wired in to provide emergency power off. It isn't mandatory, but a welcome feature for IE. I have a couple pics of some work I've done, do you mind if I post here VP.

No worries, man. Post away.
 

Tactician

Member
Thanx VP. Here are a few panels and flips I've built.... I have a lot more pix, is it kewl to post more.
 

Attachments

  • 200A Loadcenter Controller 48 x 600W.jpg
    200A Loadcenter Controller 48 x 600W.jpg
    63.8 KB · Views: 17
  • 48 ballasts 3-phase 200A.jpg
    48 ballasts 3-phase 200A.jpg
    48 KB · Views: 13
  • 3-phase loadcenter + 2 x 10 ballast flips.jpg
    3-phase loadcenter + 2 x 10 ballast flips.jpg
    55.4 KB · Views: 11
  • Panel 4.jpg
    Panel 4.jpg
    74.3 KB · Views: 10
  • Panel 7.jpg
    Panel 7.jpg
    57.3 KB · Views: 9

danks

Member
tactician those are beautifull imight have to fly you into vancouver to do a 100 lighter pm me with some details thanks.
 

Tactician

Member
Just wanted to ask why some of the panels have several Aube timers alongside the PLCs. Awesome work man!


Thanx. I used two Aube timers, they rule, because the customer wanted to be able to have two seperate controllers in the panel, so 16 ballasts on one time and 16 ballasts on the other timer.
 

Tactician

Member
This 200A three-phase panel was built for 32 x 1000W ballasts. A few extra 120V receptacles were added. Two extra 60A/240V breakers were installed to power two AC units and there are six extra 15/120V breakers to run power to circuits/receptacles in the growroom. This panel powers and controls everything.
 

Attachments

  • three phase 200A 32 x 1000w ballasts.jpg
    three phase 200A 32 x 1000w ballasts.jpg
    21.5 KB · Views: 16

Tactician

Member
Only have a few pics of this installation. The three 500A disconnects were for a 250 lighter, I had to do all the work myself, no other sparkies on site.

There were five x 200A panels for 20 ballasts each and five x 40 light flips.
 

Attachments

  • electrical room- 3 x three phase 500A disconnects.jpg
    electrical room- 3 x three phase 500A disconnects.jpg
    44 KB · Views: 13
  • 200A 20 ballast and 120V peripherals.jpg
    200A 20 ballast and 120V peripherals.jpg
    52.5 KB · Views: 9

Tactician

Member
These three cans supplied all the power for the 250 lights. The grid then fed power to the three 500A disconnects. There was a total of 12 AC units, all mounted about 10 feet high in a plenum. It was much better to have the AC units elevated, then to install a ton of ductwork.
 

Attachments

  • transformers 1.jpg
    transformers 1.jpg
    72.9 KB · Views: 12
  • AC Unit 1.jpg
    AC Unit 1.jpg
    64.3 KB · Views: 10