Hello Friends! Construction has started on my new project and I am looking for some IC insight on cooling and ventilation. What we have here is 1 structure with 4 rooms built in a garage. The structure has its own lid. Framed with 2x4's, R13 insulation, 5/8 drywall and expanded polystyrene insulated sheathing around the grow rooms. Smell outside the rooms would be very bad. Inside the garage the temps will easily go over 100 in the summer. The garage has 2 passive vents leading outside, they are aprox 6"x12" and are located near the floor. To make sure smell does not leak I want to run with negative pressure 24/7.
So this is what I came up with...
Room 1 has passive intake from garage. I am going to frame/drywall a box(aprox 20"x20"x2') on the room's lid. Top of the box will have a furnace filter as would the bottom. The lid would be cut out 20"x20" and a standard grill will be installed. Room 1 will be used as my "home office". I'm installing a window A/C in Room1....temp sensor in flower room.
Utility Room will get air from 2 passive vents (14"x8" ea). From this room there will be a duct running to an Active Air 8" fan blowing into a Growzilla hood with 2 bulbs(2k) then duct to outside the room. The Veg Room will have a passive intake, 14"x8" from the Utility Room. Then another passive intake going into the Flower Room. The Flower Room will have a carbon filter hooked up to another 8" fan ducted outside the room.
So..the million dollar question, will it work?
I was thinking of 12k btu for the AC.
Also...Since I will have two outputs, 8" each. I feel I may need to force that air directly outside via one of the garage vents?? I have more thoughts but I am stoned and better wait till I get some responses before I ramble on and on
Gotta love mspaint
So this is what I came up with...
Room 1 has passive intake from garage. I am going to frame/drywall a box(aprox 20"x20"x2') on the room's lid. Top of the box will have a furnace filter as would the bottom. The lid would be cut out 20"x20" and a standard grill will be installed. Room 1 will be used as my "home office". I'm installing a window A/C in Room1....temp sensor in flower room.
Utility Room will get air from 2 passive vents (14"x8" ea). From this room there will be a duct running to an Active Air 8" fan blowing into a Growzilla hood with 2 bulbs(2k) then duct to outside the room. The Veg Room will have a passive intake, 14"x8" from the Utility Room. Then another passive intake going into the Flower Room. The Flower Room will have a carbon filter hooked up to another 8" fan ducted outside the room.
So..the million dollar question, will it work?
I was thinking of 12k btu for the AC.
Also...Since I will have two outputs, 8" each. I feel I may need to force that air directly outside via one of the garage vents?? I have more thoughts but I am stoned and better wait till I get some responses before I ramble on and on
Gotta love mspaint