BubbleMan420

this is excellent work. looks like macguyver built this. very nice. an inovative.
 

overbudjet

Active member
Veteran
some electric

lower relay are for dehu. 2 x 15 amp 110v. 14/3
upper relay are for light 2 x 20 amp 220v. 10/2
controled by ssr (solid state relay)

Switching box (ssr controled by computer)
upper box are for high power switching 12/3 2 x 15 amp
load look like this pump 7amp 110v. UC cooling (fridge) 5 amp 110v.Some fans 4 amp 110v.And 1 (not switched) 5 amp 110v.
lower box are for low power switching 14/2 1 x 15 amp
coil relay see first pic,heat exchanger,sulfer burner,selenoid valve,


 
beautiful! Thanks for posting all the details, looks incredible. I'm REALLY looking forward to hearing about that heat exchanger set up.
 

GeorgeSmiley

Remembers
Veteran
Shit is on and poppin OB... :D

You're electrics look great man..... when I get some time with a bigger room under my belt I hope I can maximize efficiency like you have,

Inspiration man

Cheers
Smiley
 

the_dungeon

Member
AWESOME work man!! can't wait to see the finished product.

Oh, I LOVE your idea of reinforcing the rez.. might just have to use that :)
 

Anti

Sorcerer's Apprentice
Veteran
Looking good, OB! I'll be watching.

Will there be a false back of the fridge? Or will you put a lock on it or what?
 

overbudjet

Active member
Veteran
Sorry to not posting so much beeing in holiday in R.D. for last 2 week
yes it was in plan to put false back and to lock the door (fridge)by a hidden magetic lock.For now i work on my D I Y heat exchanger
 

st0ne

Member
I am intrigued by your self made chiller. A few questions if you wouldn't mind. How do you intend to control the water flow? The commercial units have a selenoid that turns on the water once the temperture reaches a set point. I often thought one could simply install a ball valve and restrict the water. Or is it even a concern to manage your water supply?

IF you have time, I would be interested to se more pictures detailing the plumbing of the chiller. I assume you just "piggyback" each radiator in series?

Very cool grow. The fridge idea is very cool, and it appears you have every detail covered. Inspiration my friend.

CheerS!
 

Dr.Dank

Cannabis 101
Veteran
respect bro great freaking grow love everything about it... your sure are doing work
and where im from you'd be hired in a heart beat.
 

easy420dude

Active member
Beautiful work.

Beautiful work.

Very impressive. I wish to hell I had your skills. Congratulations on a fine job. Enjoy.
 

overbudjet

Active member
Veteran
I am intrigued by your self made chiller. A few questions if you wouldn't mind. How do you intend to control the water flow? The commercial units have a selenoid that turns on the water once the temperture reaches a set point. I often thought one could simply install a ball valve and restrict the water. Or is it even a concern to manage your water supply?

IF you have time, I would be interested to se more pictures detailing the plumbing of the chiller. I assume you just "piggyback" each radiator in series?

Very cool grow. The fridge idea is very cool, and it appears you have every detail covered. Inspiration my friend.

CheerS!
Selenoide will be outside of the heat exchanger also having ball valve to reduce flow .the heat exchanger will always run at low pressure
Computer monitor heat at canope and if condition where meet
ex:if canope temp greater than 85 switch heat exchangeron (switch fan and open selenoid drain to waste around 2.5 gal min.).
computer/switch/s.s.r./Heat Exchanger
 